Bearing Fault Detection Helps Keep Bottling Line on Schedule

Working to Achieve

At a spirits bottling facility, the Line 2 filler pump transfers product from a storage vat to the filling equipment. Its availability is important to keeping the bottling process moving.

AVT Reliability® carries out monthly condition monitoring across the site’s operating machinery, using Machine Sentry® to capture, trend and analyse vibration data and provide the maintenance team with regular reliability reports.

The Challenge

During routine monitoring, AVT identified a step increase in vibration on the filler pump motor compared with historical readings.

Peak acceleration had risen into second alarm, suggesting that the condition was deteriorating. A failure of the pump motor could stop the filling line while the site arranged a repair, replacement or alternative product transfer route.

The priority was to identify the likely fault early enough for maintenance to be planned around production.

Our Approach

Using the Machine Sentry® mobile sensor, AVT collected vibration measurements and compared them with previous monthly results.

Vibration levels were excessive in the horizontal, vertical and axial directions. Frequency spectrum analysis revealed multiple impact peaks, bearing cage frequency sidebands and elevated broadband activity above 1,000 Hz.

Taken together, these characteristics strongly indicated developing bearing damage within the motor.

Our Findings

AVT raised an action recommending replacement of the motor bearings. The analysis gave the site a clear indication of where attention was needed and time to decide on the most practical intervention.

Rather than replacing the bearings individually, the customer chose to replace the motor.

The Solution

The maintenance team arranged the replacement motor and scheduled the work for a period when the production line was offline.

After the motor change, subsequent vibration readings returned to satisfactory levels, confirming a substantial improvement in the condition of the filler pump drive.

Our Findings

Regular condition monitoring turned an emerging vibration problem into a planned maintenance activity. The site was able to organise replacement equipment and carry out the work around production requirements, reducing its exposure to an unexpected stoppage.

The case illustrates how detailed vibration analysis can support practical decisions, even when the chosen repair differs from the initial recommendation.

At a Glance

  • Industry: Food and beverage, spirits bottling
  • Application: Line 2 filler pump
  • Equipment: Pump motor and bearings
  • Services: Vibration data collection and analysis
  • Technology: Machine Sentry® mobile sensor
  • Key finding: Elevated acceleration and frequency characteristics consistent with bearing damage
  • Solution: Motor replacement
  • Outcome: Vibration returned to satisfactory levels

Related Case Studies

Baseline Vibration Survey Reveals Weak Foundation on New Transfer Pump
Baseline Vibration Survey Reveals Weak Foundation on New Transfer Pump
Read More
Vibration Analysis Identifies Bearing Fluting
Vibration Analysis Identifies Bearing Fluting
Read More
Feed Mill Bearing Fault Detected Before Failure
Feed Mill Bearing Fault Detected Before Failure
Read More
LOG INTO MACHINE SENTRY