Rapid Vibration Diagnosis Identifies Coupling Fault on Critical Offshore Compressor
Machine Sentry® Online analysis helps pinpoint the cause of a high-vibration trip, guiding corrective action and a successful restart.
Oil & GasServices provided
Vibration AnalysisProducts used
Machine Sentry Online
Working to Achieve
When a production-critical gas compressor tripped during start-up on an offshore oil and gas installation, the maintenance team needed to understand the cause and return the machine to service with confidence.
The situation was particularly pressing. A separate compressor was already affected by a cooler leak, increasing the importance of restoring the unit that had tripped. A quick, accurate diagnosis would help the site focus its inspection and repair work where it mattered.
The Challenge
On 14 September 2026, the first-stage gas compressor tripped on high vibration at the gearbox high-speed shaft drive end (HSS DE).
The site’s senior rotating equipment engineer asked AVT Reliability® to review the start-up data and investigate what was happening within the machine. With the compressor unavailable and production capacity under pressure, the priority was to turn the available condition data into clear, practical guidance.
Our Approach
Using Machine Sentry® Online (MSO), AVT Reliability® examined the start-up vibration data alongside shaft centreline plots, phase measurements and orbit information.
Together, these views provided a more complete picture of the machine’s dynamic behaviour than an overall vibration reading alone. The analysis pointed towards a coupling fault, with indications that alignment was also contributing to the abnormal response.
AVT shared its findings and recommendations with the site on the same day as the trip, giving the maintenance team a focused direction for its investigation.
Our Findings
Inspection confirmed that a coupling lubricating-oil spray bar had sheared. The spray bar plays an essential role in supplying oil for coupling lubrication and cooling, making its failure a significant finding.
An alignment check also showed that the coupling was outside tolerance, reinforcing the need to consider the wider mechanical condition of the assembly.
The findings demonstrated the value of combining detailed rotor-dynamic analysis with targeted inspection: the data helped direct the team towards the affected components, and the physical checks established what needed attention.
The Solution
The site’s maintenance team replaced the damaged lubricating-oil spray bar.
When the compressor was restarted on 30 September 2026, vibration at the gearbox HSS DE had reduced significantly compared with the earlier start-up. The improvement provided clear evidence of the value of the diagnosis and subsequent repair.
Follow-Up
AVT Reliability® also recommended correcting the out-of-tolerance coupling alignment at the next suitable opportunity. Addressing this remaining issue offers a further opportunity to improve the machine’s vibration behaviour and long-term operating condition.
The case highlights what effective condition monitoring can deliver when it is supported by experienced analysis: not simply an indication that vibration is high, but actionable insight that helps maintenance teams identify faults, prioritise repairs and make informed decisions on critical equipment.
At a Glance
- Industry: Oil and gas
- Application: Offshore first-stage gas compression
- Equipment: Gas compressor, gearbox high-speed shaft and coupling
- Services: Vibration analysis and rotor dynamics
- Technology: Machine Sentry® Online (MSO)
- Key finding: Sheared coupling lubrication spray bar and out-of-tolerance alignment
- Outcome: Targeted repair completed; significantly reduced vibration confirmed on restart